Established 1988





Falcon 260

  • Type : Fully Automated Discrete Random Access Analyzer. Bench Top Floor Model optional
  • Throughput : 260 tests per hour Biochemistry.
  • Sample Process : Patient oriented, Batch. STAT prioritized. Continuous loading
  • Methods : End Point. Fixed Time. Kinetic. Multi Standard. Multi Reagent. Bi-chromatic
  • Test Storage : Unlimited test programs. Organ Profiles. Test Panels
  • Refrigeration : On board cooling for Reagents, Samples. Calibrators. Standards. Controls with ON/OFF Switch
  • Quality Control : program with Levy Jennings. Multiple lots. QC charts, etc.
  • Calculation : Can calculate other tests by ratio or formulas automatically
  • External Tests : Facility to input other test values and print reports


Download Brochure

SPECIFICATIONS

Dispensing System

  • Probes : 2 probes. One for Reagent & sample dispense and second for Sample mixing.
  • Probe function : Level detection, Vertical and Sideways anti-collision. Depth adjustment.
  • Probe Wash : Both probes wash in and out after every use.

Reagent System

  • Reagent Positions : 40 positions with removable tray
  • Reagent Volume : 10 ul to 400 ul with 1 ul increment, separate reagent syringe of 500 ul for better accuracy
  • Reagent Inventory : Continuous monitoring, Alarm when reagent low
  • Multiple Reagent : Up to 2 reagents per tests can be programmed

Optical System

  • Wavelengths : 9 long life wavelengths in 300 nm to 700 nm range with +/- 2 nm precision
  • Reading : Can set readings with monochromatic or bi-chromatic wavelengths
  • Abs. Range : 0.0 — 4.0 Abs.
  • Lamp : Halogen-Tungsten lamp with long life

Physical System

  • Dimension : 700 mm x 620 mm x 1200 mm (W x D x H)for Floor model
  • Weight : 60 Kgs.
  • Power Req. : 220 V, 50 Hz.

Sample System

  • Sample Positions : 40 positions with continuous loading for samples, calibrators, controls, STAT samples .
  • Container Type : Cups, Transport vials, Primary tubes, 100 ul dead volume. Alarm when sample low
  • Sample Volume : 2-50 ul with 0.1 ul increment, separate sample syringe of 50 ul for better accuracy
  • STAT Samples : STAT / Emergency samples can be added anytime and anywhere during process

Reaction System

  • Cuvettes : 90 reusable high quality cuvettes on board. Individual cuvette can be replaced if necessary
  • Read Volume : Minimum 150 ul for less reagent consumption
  • Washing : 8 steps on board washing and drying of cuvettes
  • Water Usage : 2-3 Liters per hour
  • Cuvettes Scan : All cuvettes scanned and bad cuvettes detected to avoid wrong results
  • Mixing : Mixing of Reagent and Sample in cuvette by separate mixer probe
  • Reaction Temp. : Maintained at 37*C +/- 0.1*C by dryAir bath for accurate results
  • Online Reaction : Online real time reaction curve displayed for each test

Quality Control

  • Levy Jennings Graph, Daily & Monthly charts with SD & CV


CONTACT INFO

A/11, Giriraj Industrial Estate, Opp. Ahura Center, Mahakali Caves Rd, Andheri (East) Mumbai - 400093

+91 26878783

MAP